6 Inch Double Wall Stove Pipe Selkirk
Selkirk's DSP Double Wall Stove Pipe is a connector pipe that links your wood stove to an insulated chimney. Listed & Tested to ULC S641 and UL 103 Standards. Model DSP has an attractive outer black surface made of durable aluminized steel to withstand temperatures up to 1200 degrees F in continuous operation.
-
430-alloy stainless inner wall, steel outer wall
-
Use with SuperPro and Ultra-Temp factory built chimney
-
Reduces clearances from 18" to 6" for both walls and ceilings
6" Straight
Pipe 3 metal screws supplied with each length. For installed length, subtract 1-3/8" per joint.. |
||||
|
12" Straight
Pipe 3 metal screws supplied with each length. For installed length, subtract 1-3/8" per joint.. |
||||
|
24" Straight
Pipe 3 metal screws supplied with each length. For installed length, subtract 1-3/8" per joint.. |
||||
|
36" Straight
Pipe 3 metal screws supplied with each length. For installed length, subtract 1-3/8" per joint.. |
||||
|
90 Degree Elbow Offsets obstructions as needed. Non-adjustable. Not recommended for rear exit appliances. |
||||
|
Damper Kit Allows the operator to alter the amount of air drawn through the venting system, controlling the stove’s combustion. Must be installed directly on the stove’s flue outlet where applicable. When handle is in horizontal position, the damper is “closed” (reducing combustion). The “closed” position is still 20% open, so the venting system is not completely blocked. When handle is in vertical position, the damper is wide open (no reduction of combustion). |
||||
|
Finishing Band Used to conceal the crimped end on the last length in the system. When installing, the joints appear to be going the wrong direction with a “male-end-up” connection (this is correct for the outer wall). The finishing band conceals the joints and provides a finished look. 3" high and can be trimmed. |
||||
|
Increaser Used to increase the size of the pipe to the chimney. 6" to 8" inside crimp. Image A. |
||||
|
Masonry Adaptor For installations through a masonry wall. Used to connect Double Wall Stove Pipe to an existing masonry chimney or a relined masonry chimney with stainless steel liner. Overall length is 12", the part that inserts into the chimney is 8" long. |
||||
|
Stove Adaptor May be required to adapt some stove flue outlets to Double Wall Stove Pipe. Use the adaptor to join a tee to the stove on stoves that exhaust to the back.If the stove doesn't have a lip, you can snip the tabs off a flue extension as a splice between the adaptor and stove. 6 inches high. |
||||
|
Tee With Cap Used in conjunction with a vertical insulated chimney to provide easy access for inspection and cleaning. |
||||
|
Adjustable Length Includes Finishing Band. Used to adjust pipe to desired length. Eliminates the need to cut pipe. For installed length, subtract 1-3/8" per joint. Adjustable length is 12" to 18". |
||||
|
Telescoping Length Includes Finishing Band. Easily removable for inspection and cleaning. Eliminates the need to cut pipe. For installed length, subtract 1-3/8" per joint. Telescoping length is 38" to 66". |
||||
|
Selkirk's Double Wall construction with a 1/4 inch air space between inner and outer pipe walls provides superior insulation value to the Single Wall Pipe. Superior insulation keeps flue temperatures high by enhancing draft, preventing excess smoke and build up of moisture, soot, and creosote. Double Wall Stove Pipe keeps the outer pipe temperatures cooler, which allows pipe to be installed with with a minimum of 6 inches of clearance to combustible materials, unlike the Single Wall Stove Pipe that requires a minimum of 18 inches of clearance. The inner liner is made from corrosion resistant 400 series stainless steel. Model DSP is available in a variety of lengths and elbows for easy installation. Telescopic and adjustable lengths are available to eliminate cutting-to-size and allows access to the system for cleaning and inspection. The rich black enamel paint provides a long lasting, bright finish that resists scratches. Please note: Double Wall Stove Pipe cannot be cut and still provide a proper connection to an adjoining piece of pipe. If necessary, use an adjustable length of double wall stove pipe.
Frequently Asked Questions About Stove Pipe |
A Few Words To The Wise |
1. Stick with one brand of stovepipe for connecting wood stoves to chimney.
This ensures the most secure stovepipe connection. Learn
why a good stovepipe connection is so important. |